arXiv: 2101.08084
handle: 11343/310469 , 1959.13/1440784
Abstract We propose a high-sensitivity magnetometry scheme based on a diamond Raman laser with visible pump absorption by an ensemble of coherently microwave driven negatively charged nitrogen-vacancy centres (NV−) in the same diamond crystal. The NV− centres’ absorption and emission are spin-dependent. We show how the varying absorption of the NV− centres changes the Raman laser output. A shift in the diamond Raman laser threshold and output occurs with the external magnetic field and microwave driving. We develop a theoretical framework with steady-state solutions to describe the effects of coherently driven NV− centres including the charge state switching between NV− and its neutral charge state NV0 in a diamond Raman laser. We discuss that such a laser working at the threshold can be employed for magnetic field sensing. In contrast to previous studies on NV− magnetometry with visible laser absorption, the laser threshold magnetometry method is expected to have low technical noise, due to low background light in the measurement signal. For magnetic-field sensing, we project a shot-noise limited DC sensitivity of a few pT / H z in a well-calibrated cavity with realistic parameters. This sensor employs the broad visible absorption of NV− centres and unlike previous laser threshold magnetometry proposals it does not rely on active NV− centre lasing or an infrared laser medium at the specific wavelength of the NV− centre’s infrared absorption line.
diamond Raman laser, Quantum Physics, diamond colour centres, FOS: Physical sciences, 535, 540, 530, optical micro-cavity, Raman lasers, Raman-Laser, nitrogen-vacancy centres, info:eu-repo/classification/ddc/530, Quantum Physics (quant-ph), laser threshold magnetometry
diamond Raman laser, Quantum Physics, diamond colour centres, FOS: Physical sciences, 535, 540, 530, optical micro-cavity, Raman lasers, Raman-Laser, nitrogen-vacancy centres, info:eu-repo/classification/ddc/530, Quantum Physics (quant-ph), laser threshold magnetometry
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 11 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |