image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Nephrology Dialysis ...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Nephrology Dialysis Transplantation
Article . 2001 . Peer-reviewed
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Prevention of haemodialysis‐induced hypotension by biofeedback control of ultrafiltration and infusion

Authors: R, Schmidt; O, Roeher; H, Hickstein; S, Korth;

Prevention of haemodialysis‐induced hypotension by biofeedback control of ultrafiltration and infusion

Abstract

Haemodialysis-induced hypotension is still a severe complication in spite of all the progress in haemodialysis treatment. Because of its multifactorial causes, haemodialysis-induced hypotension cannot be reliably prevented by conventional ultrafiltration and sodium profiling in open-loop systems, as they are unable to adapt themselves to actual decreases in blood pressure.A blood-pressure-guided closed-loop system, for prevention of haemodialysis-induced hypotension by biofeedback-driven computer control of both ultrafiltration and saline infusion was clinically tested in 237 treatments of seven patients prone to hypotension. As medical knowledge on multifactorial causes of hypotension is characterized by a lack in deterministic knowledge, fuzzy logic and linguistic variables were used to involve clinical experience on hypotension phenomena in terms of fuzzy knowledge. Biofeedback control is based on frequent measurements of blood pressure at 5 min intervals. Blood pressure behaviour is described by linguistic variables and fuzzy sets. Adaptive rule bases were used for the simultaneous fuzzy control of both the ultrafiltration and infusion of hypertonic saline (20% NaCl). Proper adaptation of control features to patient's conditions was provided by the critical borderline pressure, which was set by the physician individually at the beginning of each treatment. During the initial and medium phases of the sessions, ultrafiltration rates up to 150% of the average rates were applied as long as decreases in blood pressure could be compensated by saline infusion. The surplus of ultrafiltrate volume was used for blood pressure stabilization in the final phase in most instances by low ultrafiltration rates.The advantages of biofeedback-controlled haemodialysis were demonstrated by both decreasing the frequency of hypotonic episodes and by increasing or maintaining constant levels of systolic blood pressure during the final phase in 88% of treatments. As saline infusion was applied mainly in the initial and medium phases, blood sodium levels were not significantly higher at the end of the sessions, and interdialytic weight gain was not elevated.The application of fuzzy logic in the blood-pressure-guided biofeedback control of ultrafiltration and sodium infusion during haemodialysis is able to minimize haemodialysis-induced hypotension.

Related Organizations
Keywords

Saline Solution, Hypertonic, Fuzzy Logic, Renal Dialysis, Sodium, Humans, Ultrafiltration, Biofeedback, Psychology, Blood Pressure, Hypotension

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    34
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
34
Top 10%
Top 10%
Top 10%
bronze