A novel lumen-apposing stent for transluminal drainage of nonadherent extraintestinal fluid collections

Authors: K F, Binmoeller; J, Shah;

A novel lumen-apposing stent for transluminal drainage of nonadherent extraintestinal fluid collections

Abstract

Tubular stents have been used to accomplish endoscopic transluminal drainage, but do not impart lumen-to-lumen anchorage. We evaluated a novel lumen-apposing stent designed for enteric drainage of nonadherent lumens.Ex vivo benchtop testing was performed to quantify various physical and performance metrics of the stent (Axios). A simulator was developed to test the stent deployment through an echoendoscope. Survival experiments were performed on four pigs. Under endosonographic guidance, a cholecystogastrostomy tract was created and the stent was deployed across the lumens. Direct cholecystoscopy was performed. Surveillance gastroscopy was performed at weekly intervals for up to 8 weeks. Measured outcomes were procedural success, safety, and device durability and patency.In benchtop testing, the Axios stent withstood various vector forces of movement, yet allowed easy removability from the simulated tissue. The stent was successfully deployed across the stomach and gallbladder lumens in all four animals without complication. Direct cholecystoscopy and contrast injection documented the absence of tissue trauma and leakage. Gastroscopy at weekly intervals showed the stent in stable position without dislodgment. The stent remained patent in all animals. The covering remained intact and there was no hyperplastic tissue ingrowth or overgrowth, or tissue injury. One stent was removed at 4 weeks. On necropsy, the gallbladders showed focal adherence to the stomach at the site of cystogastrostomy with a negative leak test.The Axios stent enables the creation of a robust and reliable conduit between nonadherent lumens around the gastrointestinal tract.

Related Organizations
Keywords

Sus scrofa, Gallbladder, Equipment Design, Body Fluids, Endosonography, Gastroscopy, Intestine, Small, Animals, Drainage, Female, Stents, Stress, Mechanical, Device Removal

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    210
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 1%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 1%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
210
Top 1%
Top 1%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!