Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Griffith Research On...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
JBIC Journal of Biological Inorganic Chemistry
Article . 2018 . Peer-reviewed
License: Springer TDM
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

The role of citrate, lactate and transferrin in determining titanium release from surgical devices into human serum

Authors: Curtin, Justin P.; Wang, Minji; Cheng, Tianfan; Jin, Lijian; Sun, Hongzhe;

The role of citrate, lactate and transferrin in determining titanium release from surgical devices into human serum

Abstract

The presence of ionic titanium in the serum of patients with titanium implants is currently unexplained. This is presumed due to corrosion, and yet the serum titanium concentration measured in patients is far greater than that predicted by its solubility. The binding of titanium ion as Ti(IV) to human transferrin (hTF) in serum indicates that Ti(IV) ions interact with human physiology. This is an intriguing finding since there is currently no known role for titanium ions in human physiology. Thus, understanding the factors that determine in vivo titanium ion release is relevant to further understanding this metal's interactions with human biochemistry. The present study sought to determine the extent of titanium ion release of into human serum in vitro, and the role of citrate, lactate and hTF in this process. It was found that, when surgical devices of commercially pure titanium were placed into human serum, citrate and lactate concentrations were the prime determinants of titanium release. Crystallography revealed Ti(IV) bound to hTF in the presence of citrate alone, signalling that citrate can act as an independent ligand for Ti(IV) binding to hTF. Based on these findings, a two-stage process of titanium ion release into human serum that is dependent upon both citrate and hTF is proposed to explain the ongoing presence of titanium ion in human subjects with implanted titanium devices.

Country
Australia
Related Organizations
Keywords

Serum, Titanium, Biochemistry & Molecular Biology, Science & Technology, Crystallography, Transferrin, 600, Prostheses and Implants, Citric Acid, Corrosion, Chemistry, Inorganic & Nuclear, Biochemistry and cell biology, Physical Sciences, Medicinal and biomolecular chemistry, Microscopy, Electron, Scanning, Humans, Lactic Acid, Life Sciences & Biomedicine, Inorganic chemistry

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    13
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
13
Top 10%
Average
Top 10%
Green