Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Graefe s Archive for...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Graefe s Archive for Clinical and Experimental Ophthalmology
Article . 2009 . Peer-reviewed
License: Springer TDM
Data sources: Crossref
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Graefe s Archive for Clinical and Experimental Ophthalmology
Article . 2009 . Peer-reviewed
License: Springer TDM
Data sources: Crossref
versions View all 3 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Intraocular pressure measured by dynamic contour tonometer and ocular response analyzer in normal tension glaucoma

Authors: Tetsuya, Morita; Nobuyuki, Shoji; Kazutaka, Kamiya; Mana, Hagishima; Fusako, Fujimura; Kimiya, Shimizu;

Intraocular pressure measured by dynamic contour tonometer and ocular response analyzer in normal tension glaucoma

Abstract

To investigate intraocular pressure (IOP) measurement values in normal tension glaucoma (NTG) eyes using two different types of tonometer that are supposed to be little affected by corneal biochemical properties.This study included 30 normal eyes of 16 healthy subjects and 30 eyes of 16 patients with NTG. IOP was measured with a Goldmann applanation tonometer (GAT), a Pascal dynamic contour tonometer (DCT), and a Reichert ocular response analyzer (ORA) three times each for normal and NTG eyes. The main measures were GAT-IOP, DCT-IOP, corneal-compensated IOP (IOPcc), Goldmann-correlated IOP (IOPg), and central corneal thickness (CCT).In normal eyes, GAT-IOP was 13.2 +/- 1.4 mmHg; DCT-IOP, 13.0 +/- 1.6 mmHg; IOPcc, 13.6 +/- 2.0 mmHg; and IOPg, 12.4 +/- 2.0 mmHg. Multivariate analysis revealed no significant differences between the four measurements (p = 0.08). CCT was 524.6 +/- 27.3 microns. In NTG eyes, GAT-IOP was 13.1 +/- 1.3 mmHg; DCT-IOP, 13.7 +/- 1.3 mmHg; IOPcc, 15.2 +/- 2.0 mmHg; and IOPg, 12.7 +/- 2.0 mmHg. Multivariate analysis showed significant differences between the four measurements (p < 0.01). Sheffé's test showed that IOPcc was significantly higher than GAT-IOP, DCT-IOP, and IOPg (GAT-IOP vs IOPcc: p < 0.0001; DCT-IOP vs IOPcc: p = 0.01; IOPcc vs IOPg: p < 0.0001). CCT was 515.4 +/- 32.9 microns, with no significant difference between normal and NTG eyes (p = 0.15).We investigated the values of IOP in NTG eyes as measured by the DCT and ORA. IOPcc was significantly greater than GAT-IOP, DCT-IOP and IOPg in NTG eyes, suggesting the possibility that IOP values may be underestimated.

Keywords

Adult, Cornea, Male, Tonometry, Ocular, Humans, Female, Middle Aged, Glaucoma, Open-Angle, Intraocular Pressure, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    21
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
21
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!