Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Journal of Intensive...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

I-TRACH: Validating A Tool for Predicting Prolonged Mechanical Ventilation

Authors: Paul A, Clark; Ryan C, Inocencio; Christopher J, Lettieri;

I-TRACH: Validating A Tool for Predicting Prolonged Mechanical Ventilation

Abstract

Purpose: We previously developed a bedside model (I-TRACH), which used commonly obtained data at the time of intubation to predict the duration of mechanical ventilation (MV). We now sought to validate this in a prospective trial. Methods: A prospective, observational study of 225 consecutive adult medical intensive care unit patients requiring MV. Utilizing the original 6 variables used in the I-TRACH model (Intubation in the ICU, Tachycardia [heart rate > 110], Renal dysfunction [blood urea nitrogen > 25], Acidemia [pH < 7.25], Creatinine [>2.0 or >50% increase from baseline values], and decreased HCO3 [<20]), we (1) confirmed that these were still predictive of length of MV by multivariate analysis and (2) assessed the correlation between the number of criteria met and the subsequent duration of MV. In addition, we compared the performance of I-TRACH to Acute Physiology Age Chronic Health Evaluation-II and III, Sequential Organ Failure Assessment, and Acute Physiology Score as predictors of length of MV. Results: Mean age was 62.6 ± 18.7 years, with a mean duration of MV of 5.8 ± 5.7 days. The number of I-TRACH criteria met directly correlated with the duration of MV. Individuals with ≥4 criteria were significantly more likely to require MV >7 and >14 days. Similarly, those who remained on ventilators for both >7 and >14 days met significantly more I-TRACH criteria than those requiring shorter durations of MV (1.7 ± 1.3 vs 2.8 ± 1.3 vs 3.8 ± 1.3 criteria, P < .001). I-TRACH performed better than all other models used to predict the duration of MV. Conclusion: Similar to our previous retrospective study, these findings validate I-TRACH in determining the subsequent need for MV >7 and >14 days at the time of intubation.

Keywords

Adult, Male, Time Factors, Hydrogen-Ion Concentration, Middle Aged, Kidney, Respiration, Artificial, Severity of Illness Index, Bicarbonates, Intensive Care Units, Point-of-Care Testing, Creatinine, Tachycardia, Intubation, Intratracheal, Humans, Female, Prospective Studies, Acidosis, Ventilator Weaning, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    14
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
14
Top 10%
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!