Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Clinical Optometryarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
PubMed Central
Conference object . 2019
License: CC BY NC
Data sources: PubMed Central
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Clinical Optometry
Article . 2019 . Peer-reviewed
License: CC BY
Data sources: DOAJ
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Dove Medical Press
Review . 2019 . Peer-reviewed
Data sources: Dove Medical Press
versions View all 4 versions
addClaim

Posterior corneal astigmatism: a review article.

Authors: Mohammadi,Seyed-Farzad; Khorrami-Nejad,Masoud; Hamidirad,Moein;

Posterior corneal astigmatism: a review article.

Abstract

Most human eyes show at least a small degree of corneal astigmatism and it can arise from both surfaces of the cornea. The shape of the anterior corneal surface provides no definitive basis for knowing the toricity of the posterior surface. In the previous studies, average astigmatism of the posterior corneal surface was -0.26 to -0.78 diopter. The radius of the posterior corneal surface is less than the radius of the anterior corneal surface. Most studies have found a clear correlation between the anterior and posterior corneal asphericities and the asphericity of the posterior surface is independent of the vertex radius of curvature, refractive error and gender. In contrast to the anterior corneal surface, the asphericity of the posterior corneal surface varies significantly between meridians. The anterior and posterior corneal surface would have approximately parallel principal meridians and both of these surfaces are often flatter in the horizontal meridian than the vertical one. This is especially true in the higher degrees of corneal astigmatism, and then about 10% of any anterior corneal astigmatism is neutralized by an astigmatism arising from the posterior corneal surface. Although the second corneal surface only contributes to about 10% of the total refractive power of the eye, a precise knowledge of its morphology is needed for the correct diagnosis and monitoring the corneal diseases or the surgical interventions and in many eyes neglecting the posterior corneal surface measurement may lead to significant deviations from the corneal astigmatism estimation. In this article, we have reviewed the shape and the toricity of the posterior corneal surface and also the effect of age on it. We investigated the contribution of posterior corneal astigmatism to the total corneal astigmatism and evaluated the accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement.

Related Organizations
Keywords

Cornea, Ophthalmology, Corneal toricity, Clinical Optometry, Review, RE1-994, Posterior corneal astigmatism

  • BIP!
    Impact byBIP!
    citations
    The total number of citations received by all articles of the researcher of interest.
    37
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
The total number of citations received by all articles of the researcher of interest.
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
37
Top 10%
Top 10%
Top 10%
Green
gold