Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability.

Authors: Meredith, N; Friberg, B; Sennerby, L; Aparicio, C;

Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability.

Abstract

The Periotest is an electronic instrument that has been advocated for the measurement of implant stability and osseointegration. The aims of this investigation were to establish the relationship between contact time and PTV values when the Periotest was used to assess implants in vivo and in vitro, and to investigate the influence of the striking height of the Periotest handpiece and the length of implant abutment.The accelerometer signal from a Periotest was captured and compared with the resulting PTV value. In vitro measurements of PTV and contract time were performed on a 3-mm abutment that had been attached to a 15-mm implant luted into an aluminium block, and were repeated on a patient in vivo. further measurements were made of the abutments of six implants in turn in the maxilla of the same patient. The standard abutment lengths on the implants were 3, 4 (x 2), 5.5 (x 2), and 7 mm.The results indicated that there was a linear relationship between contact time and PTV value for implants measured in vitro and in vivo. Greater scatter of the in vivo data was attributed to test and patient variables including striking position, distance, and damping as a result of the presence of soft tissue. There was a linear relationship between the PTV value and the striking height for implant measurements in vivo and in vitro.It can be concluded that the sensitivity of the Periotest to clinical variables including striking heights and handpiece angulation limit the application of the instrument as a clinical diagnostic aid to measure implant stability.

Country
Australia
Related Organizations
Keywords

Mobility, Dental Implants, Time Factors, Diagnosis, Oral, Reproducibility of Results, Dental Abutments, Equipment Design, Percussion, Evaluation Studies as Topic, Osseointegration, Materials Testing, Humans

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    89
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 1%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
89
Top 10%
Top 1%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!