Automatic adaptation of the basic pacing rate in response to minute ventilation. Chorum French Investigational Group.

Authors: M, Limousin; G, Pioger; J L, Bonnet; L, Geroux;

Automatic adaptation of the basic pacing rate in response to minute ventilation. Chorum French Investigational Group.

Abstract

Rate responsive pacing based on minute ventilation (VE) correlates highly with metabolic demand. This type of sensing also recognizes extended periods of rest. The Chorum pacemaker includes a rate responsive algorithm that modulates the basic rate according to phases of activity versus sleep. Forty-six patients (mean age 78 +/- 15), received a Chorum pacemaker for atrioventricular block in 17 cases, sick sinus syndrome in 25, and mixed disorders in 4. Holter monitoring was performed to analyze to heart rate and to examine the circadian adaptation of the minimal pacing rate. The mean basic rate was programmed at 63 +/- 5 beats/min, and the sleep rate at 52 +/- 4 beats/min. Seventeen patients had spontaneous heart rates consistently above the programmed basic rate, and 6 had sustained supraventricular tachyarrhythmias. One-half of the patients had periods of pacing at the programmed sleep rate. The mean diurnal pacing rate was 68 +/- 5 beats/min compared to a mean nocturnal rate of 60 +/- 4 beats/min (P < 0.0001). The average time spent at the basic rate was 37 +/- 30 min (0-110) during daytime (4%), versus 242 +/- 153 min (20-477) at night (45%, P < 0.0001). No adverse effect was observed in this patient population. VE allows a reliable detection of the sleeping periods as well as an adjustment of the basic rate in accordance. Caution is advised in cases of bradycardia dependent tachyarrhythmias.

Keywords

Male, Sick Sinus Syndrome, Pacemaker, Artificial, Cardiac Pacing, Artificial, Pilot Projects, Equipment Design, Middle Aged, Circadian Rhythm, Electrodes, Implanted, Heart Block, Heart Rate, Electrocardiography, Ambulatory, Humans, Female, Pulmonary Ventilation, Sleep, Algorithms, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    6
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
6
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!