Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

The use of the Periotest value as the initial success criteria of an implant: 8-year report.

Authors: C, Aparicio;

The use of the Periotest value as the initial success criteria of an implant: 8-year report.

Abstract

Osseointegration is a histometric process that occurs gradually over a period of time. The load that an implant is able to bear depends upon, among other parameters, the quality of the bone-implant contact. For 8 years the damping capacity of 1,182 Brånemark implants inserted consecutively in 315 patients was measured using the Periotest method. The following clinical observations were made: (1) a relationship was found between implants with a specific Periotest value range that, at the moment of the transepithelial connection, were considered to be clinically stable, asymptomatic, and whose radiograph image was not radiolucent; (2) a relationship was found between clinically nonintegrated implants with a different Periotest value range; (3) variations in the Periotest value were related to the type of bone in which the implant was placed; (4) a small percentage of borderline implants with a Periotest value between the osseointegrated and the nonosseointegrated Periotest values was detected; (5) the percentage of secondary failures was related to an initial Periotest value corresponding to a borderline implant; (6) the healing time of each implant was individualized in accordance with the successively obtained Periotest value; (7) the load and the design of the prosthesis were individualized; (8) early detection of failing implants before fabrication of prostheses is possible; (9) communication was improved between the surgeon and the prosthodontist; and (10) variations in Periotest value were related to bone remodeling. The sensitivity of the principal clinical test in evaluating osseointegration is discussed regarding the moment of its application. The use of Periotest values as an initial success criteria of an implant is proposed.

Related Organizations
Keywords

Dental Implants, Titanium, Time Factors, Diagnosis, Oral, Dental Implantation, Endosseous, Dental Abutments, Percussion, Sensitivity and Specificity, Osseointegration, Humans, Dental Restoration Failure, Longitudinal Studies, Dental Alloys

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    36
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
36
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!