We previously reported about the room air contamination during ventilation study using the TECHNEGAS system. Main cause of the contamination with radioactive gas were leakage through the filter and expiration of the patient after the inhalation. Then, a new type filter was developed to reduce the radioactive leakage. The efficacy and usefulness of the new type filter was examined. The radioactive leakage through the new filter was markedly reduced to 1/6 compared with the old type. But the air resistance of passage was increased over two times of the old type. This resistance is not able to disregard on respiratory physiology. Improvement to reduce the resistance is desirable.
Radiation Protection, Air Pollution, Indoor, Humans, Air Pollution, Radioactive, Filtration, Sodium Pertechnetate Tc 99m
Radiation Protection, Air Pollution, Indoor, Humans, Air Pollution, Radioactive, Filtration, Sodium Pertechnetate Tc 99m
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |