Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Impulse oscillometry and body position].

Authors: D, Drews; J, Vogel; A, Wilke; H J, Smith;

[Impulse oscillometry and body position].

Abstract

To assess diurnal profiles of impulse-oscillometry (IOS) changes of IOS-parameters between different body positions have been studied using a special set IOS-Bedside for individual home care. IOS has been applied in lateral lying and in sitting position in 20 healthy female and male probands, aged 10-67, during 24 hours in intervals of 3 hours. In each test during normal breathing for approximately 30 sec about 130 spectral and structural analyses have been performed at an impulse distance of 0.2 sec. The global means of resistance at 5 Hz (R5) in lying position are in men about 0.6 and in women about 0.3 hPa/l/s higher than in sitting position, those of reactance in men and women are only about 0.2 hPa/l/s lower. There is a distinct diurnal periodicity of the differences. The maxima of them may occur at different hours of the day in single probands; but at the average mean the maxima are found at the end of night. The differences of oscillation parameters between lying and sitting position are bigger at end-expiration than at end-inspiration. The resistance-flow-gradients, representing the component of turbulent flow, are enlarged in lying position especially at night.

Keywords

Adult, Male, Time Factors, Adolescent, Airway Resistance, Posture, Reproducibility of Results, Middle Aged, Circadian Rhythm, Oscillometry, Humans, Female, Child, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!