Use of the laryngeal mask for closed circuit anesthesia.

Authors: M R, Stacey; S, Morris; T, Asai;

Use of the laryngeal mask for closed circuit anesthesia.

Abstract

We examined whether the laryngeal mask could be used effectively in 70 patients breathings spontaneously during closed-circuit anesthesia. After administration of oxygen 101.min-1, anesthesia was induced and the laryngeal mask inserted. After 6 min of denitrogenation (3.51.min-1 nitrous oxide and 1.51.min-1 oxygen), the fresh-gas flow was decreased to the minimum required to maintain refilling of a ventilator bellows (Carden Ventmasta); nitrous oxide was turned off. A vaporiser outside the breathing system was set either by observing an end-tidal agent monitor or at 3-5 times greater than the required end-tidal concentration. The total fresh gas flow, hemodynamics and respiratory variables were monitored. Several types of operations were performed and lasted 9-126 min (mean 37 min). The average total fresh gas flow during the closed circuit period was 340 ml.min-1 (range 200-500 ml.min-1). Blood pressure, heart rate and respiration were stable throughout anesthesia and there were no major side effects attributable to the technique. We believe that closed-circuit anesthesia in patients breathing spontaneously through the laryngeal mask, as described here, can be used safely, conveniently and effectively. This technique is suitable for surgical operations of short duration.

Related Organizations
Keywords

Adult, Male, Adolescent, Isoflurane, Middle Aged, Laryngeal Masks, Enflurane, Anesthesia, Closed-Circuit, Anesthetics, Inhalation, Humans, Female, Aged, Monitoring, Physiologic

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!