[Continuous measurement of mixed venous oxygen saturation].

Authors: L, Hannemann; K, Reinhart;

[Continuous measurement of mixed venous oxygen saturation].

Abstract

The task of the cardiorespiratory system is to deliver enough oxygen to meet the metabolic requirements of the body. Of all metabolic substrates, oxygen has the highest percentage of extraction and oxygen reserves are exhausted within a few minutes. Arterial oxygen content and cardiac output are the determinants of oxygen delivery (DO2). O2-delivery in intensive care patients can be compromised by many factors, especially diminished O2-uptake in the lung, reduced hemoglobin content, and/or altered cardiac performance. To calculate DO2, determination of cardiac output (CO), O2-tension, O2-saturation, and hemoglobin is necessary. O2-consumption (VO2), the best mirror of the actual global metabolic activities of the tissues, can be measured invasively using arterial-venous O2-content difference (avDO2) and cardiac output, which requires pulmonary artery catheterization. The body has two basic mechanisms to meet increased VO2 or to compensate for a decrease in DO2: an increase in CO and a rise in O2-extraction ratio. The avDO2 and O2-extraction ratio are known to be very good indicators for the adaptation of the cardiorespiratory system to the actual metabolic requirements of the body. The oxygen supply-to-demand ratio (DO2/VO2) yields information on the extent to which these compensatory mechanisms either function or fail. It was demonstrated that changes of the avDO2 and changes of the DO2/VO2 are always paralleled unidirectionally by changes of mixed venous O2-saturation (SvO2). Therefore these parameters can easily be replaced by SvO2 for clinical purposes. Continuous real time in-vivo control of SvO2 has now become possible using commercially available devices with fiberoptic catheters. Pathophysiological changes in the O2-supply-to-demand-ratio as well as effects of ongoing therapy can be determined at the bedside.

Related Organizations
Keywords

Oxygen, Hemodynamics, Hemoglobinometry, Humans, Monitoring, Physiologic

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    2
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
2
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!