[Safety applications in apnea test].

Authors: T, Maekawa; D, Sadamitsu; A, Tateishi;

[Safety applications in apnea test].

Abstract

Apnea test for brain death determination is able to perform easily with the method written in Japanese criteria (Brain death study group, Ministry of Health and Welfare, 1987) (Figure 3). PaCO2 is increased to more than 60 mmHg, by which respiratory center in the brain stem is stimulated enough. Hypoxemia may occur and is the most serious complication during apnea test. We examined O2 delivery methods either by a thin cannula inserted to near tracheal carina (Ordinary method, 6 l/min) or by constant flow using a ventilator (6 l/min, or 20 l/min). During 10 minutes apnea test, PaO2 and PaCO2 changed significantly from 429 to 264 mmHg and 43 to 90 mmHg, respectively. But there was no significance between the methods. During apnea test, we have to distinguish spinal reflex movement from spontaneous respiratory movement. It is better to keep body temperature near 37 degrees C, because low body temperature requires much longer duration to reach required PaCO2, 60 mmHg (y = 0.54x - 15.2, where x is body temperature, degrees C and y is delta PaCO2, mmHg/min). Hypoxemia during apnea test must be prohibited, because it may cause farther organ damage. Maintenance of oxygenation during apnea test is difficult in patients who have severe respiratory failure. Oxygenation is kept much higher by adding positive airway pressure (10 cm H2O) and continuous monitoring of oxygenation by a pulse oxymeter prepares much safer apnea test in these patients.

Related Organizations
Keywords

Neurologic Examination, Brain Death, Apnea, Respiration, Humans, Carbon Dioxide, Hypoxia

  • BIP!
    Impact byBIP!
    citations
    The total number of citations received by all articles of the researcher of interest.
    2
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
The total number of citations received by all articles of the researcher of interest.
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
2
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!