[Balloon atrioseptostomy under color flow Doppler echocardiography guidance].

Authors: T, Kobayashi; S, Kyo; E, Takanawa; R, Omoto;

[Balloon atrioseptostomy under color flow Doppler echocardiography guidance].

Abstract

The clinical effectiveness and safety of balloon atrioseptostomy (BAS) under color flow mapping Doppler echocardiography (CFM) guidance was evaluated in 21 BAS procedures performed on 19 patients with cyanotic heart disease (d-TGA 15, PA 1, TA 2, Ebstein's anomaly PA + supramitral ring 1) in the cardiac catheterization laboratory (16 patients) or in the intensive care unit (ICU 3 patients). The indication for BAS was established based on CFM diagnosis. BAS was performed with combined CFM and X-ray guidance on 16 patients prior to cardiac catheterization, and with CFM guidance only on 3 patients in the ICU. A series of BAS was performed until satisfactory interatrial opening was obtained and a complete hemodynamic study was performed by CFM and catheterization after BAS, if possible. In all 19 patients BAS was performed very safely with positioning of balloon in the left atrium, selection of appropriate size of balloon, and the confirmation of the effect of BAS provided by CFM guidance at each step. The size of the interatrial opening was significantly increased from 2.6 to 8.1 mm (p < 0.01) after a series of BAS and the arterial oxygen saturation was significantly increased from 44 to 75% (p < 0.01). CFM provides effective diagnosis and guidance for BAS in severely cyanotic neonates with congenital heart disease, and should significantly contribute to the speed, efficacy, and safety of the procedure.

Keywords

Heart Defects, Congenital, Male, Transposition of Great Vessels, Infant, Newborn, Infant, Echocardiography, Doppler, Catheterization, Heart Septum, Humans, Female, Heart Atria

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!