Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Sources of error in the pre-analytical phase of blood gas analysis].

Authors: W A, Wuillemin; A U, Gerber;

[Sources of error in the pre-analytical phase of blood gas analysis].

Abstract

Analysis of blood gases and blood pH yield important information in many situations of clinical emergencies. We report on a patient in whom pre-analytic errors in blood gas and blood pH measurements resulted in unnecessary further investigations. We therefore studied various pre-analytic sources of error in blood pH and blood gas analysis. Delay in sample processing for more than one hour resulted in an increase of pO2 and pCO2 and a decrease of pH. Excess sodium heparin solution as an anticoagulant (> or = 10% of total volume) led to a significant decrease of pH and pCO2 and to an increase of pO2. Air bubbles (10% of total volume) left in the syringe for 10 min significantly increased pO2. For accurate estimations of pO2, pCO2 and pH, it is necessary to keep the heparin solution below 10% of total volume, to expel all air bubbles from the syringe and to process the blood sample within one hour. Instructions to medical staff on handling blood samples for blood gas analysis should include these possible sources of errors.

Keywords

Oxygen, Time Factors, Heparin, Humans, Female, Blood Gas Analysis, Carbon Dioxide, Diagnostic Errors, Aged, Specimen Handling

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!