Precision attachment-retained removable partial dentures: Part 2. Long-term study of ball attachments.

Authors: Öwall, B.;

Precision attachment-retained removable partial dentures: Part 2. Long-term study of ball attachments.

Abstract

Patients provided with 24 ball attachment-retained removable partial dentures were followed up to 23.5 years. The prosthetic treatment included fixed partial dentures in 8 arches, and combinations of crowns and splint bars in 16 arches. All ball attachment matrices were supplied with vertical occlusal stops in contact with the patrices. A nonresilient hinged coupling was established between fixed partial dentures and removable partial dentures. Seventeen arches had only two or three remaining teeth. A total of 66 abutments for fixed partial dentures were included, 30 of which were root canal treated and supplied with posts. No technical failures (loss of retention/cement failure, root or tooth fracture, metal framework fracture) with the fixed partial dentures were recorded. With the removable partial dentures, additional retention with clasps was introduced in 2 of the dentures (in addition to 8 originally), 2 had to be remade after fractures, and 4 dentures were relined.

Country
Denmark
Related Organizations
Keywords

Adult, Aged, 80 and over, Male, Middle Aged, Denture Retention, Prosthesis Failure, Dental Clasps, Patient Satisfaction, Denture Precision Attachment, Denture, Partial, Removable, Humans, Female, Denture Design, Aged, Follow-Up Studies

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    18
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
18
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!