Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Humidifier lung].

Authors: P, Gerber; R, de Haller; W J, Pyrozynski; E R, Sturzenegger; O, Brändli;

[Humidifier lung].

Abstract

Breathing air from a humidifier or an air conditioning unit contaminated by various microorganisms can cause an acute lung disease involving fever, cough and dyspnea, termed "humidifier fever". This type of hypersensitivity pneumonitis was first described in 1959 by PESTALOZZI in the Swiss literature and subsequently by BANASZAK et al. in the Anglo-American. Here a chronic form of this disease which led to pulmonary fibrosis is described: A 37-year-old woman who works in a cheese shop presented with dyspnea which had been progressive over two years, weight loss, a diffuse reticular pattern radiographically and a severe restrictive defect in lung function tests. Open lung biopsy revealed chronic interstitial and alveolar inflammation with non-caseating granulomas and fibrotic changes. Circulating immune complexes and precipitins against the contaminated humidifier water and cheese mites were found, but no antibodies suggesting legionnaires' disease. Two out of five otherwise healthy employees of this cheese shop, where a new humidifying system had been installed 7 years earlier, also had precipitins against the contaminated water from the humidifier and the cheese mites. Despite ending of exposure and longterm steroid and immunosuppressive therapy, the signs and symptoms of pulmonary fibrosis persisted. Contrary to the acute disease, this chronic form is termed "humidifier lung". The importance is stressed of investigating the possibility of exposure to contaminated humidifiers or air conditioning units in all cases of newly detected pulmonary fibrosis.

Keywords

Adult, Occupational Diseases, Mites, Pulmonary Fibrosis, Humans, Air Conditioning, Female, Allergens, Alveolitis, Extrinsic Allergic

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    3
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
3
Average
Top 10%
Average
Related to Research communities
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!