Within a study of standard values, investigations of the static and dynamic lung compliance were performed in 162 test persons in a good state of health of heart and lungs. Age, size, constitution, and intrathoracical gas volume are necessary parameters for calculation of an individual standard value of the dynamic compliance, whereas age and intrathoracical gas volume only are needed for calculation of a standard value of the static compliance. The new standard values are compared with the values known from the literature.
Adult, Male, Adolescent, Body Weight, Age Factors, Middle Aged, Body Height, Reference Values, Humans, Female, Lung Volume Measurements, Lung Compliance, Aged
Adult, Male, Adolescent, Body Weight, Age Factors, Middle Aged, Body Height, Reference Values, Humans, Female, Lung Volume Measurements, Lung Compliance, Aged
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 3 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |