Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Clinical Outcomes of Hydrus Microstent Implantation for Open-Angle Glaucoma: Results from a Large Academic Center.

Authors: Natalie R, Hamilton; Anam, Akhlaq; Patrick O, Nnoromele; Nicolas, Gasquet; Catalina, Garzon; Yulia, Nam; Leangelo, Hall; +7 Authors

Clinical Outcomes of Hydrus Microstent Implantation for Open-Angle Glaucoma: Results from a Large Academic Center.

Abstract

To assess the clinical outcomes of Hydrus Microstent implantation with cataract extraction for the treatment of open-angle glaucoma (OAG) over a maximum of 4 years.A retrospective, single-center, single-arm, longitudinal cohort study.Three hundred eight patients (464 eyes) with OAG who underwent Hydrus Microstent implantation with cataract extraction between February 2019 and December 2021, followed for a median of 2.0 (interquartile range [IQR], 1.3-2.8) years.Medical records were reviewed to collect demographic and clinical data. After assessment for Gaussian distribution, mean and standard deviation (SD) or median and IQR were calculated. Change from baseline was calculated with mixed-effects models and expressed as mean change and standard error.(1) Intraocular pressure (IOP); (2) number of glaucoma medications; (3) need for additional glaucoma procedures; and (4) rate of glaucoma progression, calculated using mean deviation (MD) from standard automated perimetry and OCT peripapillary retinal nerve fiber layer (RNFL) thickness.Among 308 patients, 60.7% (n = 187) were White, and 50.6% (n = 156) were female. The median age was 74 (IQR, 68-78) years. Most eyes had mild (63.8%) or moderate (23.9%) OAG. Of 464 eyes, 99 (21.4%) had undergone prior procedures for glaucoma. At baseline, the mean (±SD) IOP was 16.0 ± 3.7 mmHg while taking 1.9 ± 1.1 glaucoma medications. After Hydrus implantation, a sustained reduction was observed in mean IOP [mean change ± standard error]: -1.9 ± 0.3 at 6 months (P < 0.0001), -1.2 ± 0.2 at 1 year (P < 0.0001), -1.2 ± 0.2 at 2 years (P < 0.0001), -1.6 ± 0.3 at 3 years (P < 0.0001), and -1.2 ± 0.7 at 4 years (P = 0.02). Glaucoma medications were reduced by 1.2 ± 0.1 at 6 months (P < 0.0001), 1.1 ± 0.1 at 1 year (P < 0.0001), 1.0 ± 0.1 at 2 years (P < 0.0001), 0.9 ± 0.1 at 3 years (P < 0.0001), and 0.5 ± 0.2 at 4 years (P = 0.03). Only 14 eyes (3.2%) required additional glaucoma procedures. Compared to the lookback period, the rates of visual field MD and RNFL loss decreased in the postoperative period by 0.18 ± 0.08 dB/year (-0.18 ± 0.02 vs. 0.004 ± 0.08 dB/year, P = 0.02) and 0.51 ± 0.29 μm/year (-0.47 ± 0.12 vs. 0.04 ± 0.21 μm/year, P = 0.07), respectively.In this nontrial setting, cataract surgery with Hydrus Microstent implantation was associated with sustained reductions in IOP, glaucoma medication burden, and disease progression rate.Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Related Organizations
Keywords

Male, Academic Medical Centers, Visual Acuity, Middle Aged, Treatment Outcome, Humans, Female, Stents, Visual Fields, Glaucoma Drainage Implants, Glaucoma, Open-Angle, Intraocular Pressure, Tomography, Optical Coherence, Retrospective Studies, Aged, Follow-Up Studies

  • BIP!
    Impact byBIP!
    citations
    The total number of citations received by all articles of the researcher of interest.
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
The total number of citations received by all articles of the researcher of interest.
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!