Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Validation study of a novel diaphragmatic excursion measurement method: evaluation of diaphragmatic excursion by phased-array probe in hepato-renal/spleno-renal section].

Authors: Junyu, Ma; Shanshan, Zhai; Xiaocong, Sun; Chen, Li; Jun, Duan;

[Validation study of a novel diaphragmatic excursion measurement method: evaluation of diaphragmatic excursion by phased-array probe in hepato-renal/spleno-renal section].

Abstract

To investigate the accuracy and reproducibility of diaphragmatic excursion (DE) measurements through hepato-renal/spleno-renal section as a novel method for assessing diaphragmatic function.Twelve healthy participants were recruited. Each participant underwent DE measurements performed by four operators with varying levels of experience using traditional methods (liver/spleen section) and novel methods (hepato-renal/spleno-renal section), respectively. Among them, two experienced operators were critical care clinicians, and diaphragmatic ultrasound was performed in more than 50 cases. The other two inexperienced operators were respiratory therapists, with less than 10 cases of diaphragmatic ultrasound operations, who received a 2-hour theoretical and operational training before the study. Operators initially used the conventional method with a 1.5-6.0 MHz convex probe in M-mode, placing the sampling line perpendicular to the diaphragm at the point of maximum excursion, and the liver/spleen section DE was determined during normal breathing of participant. Then, they used the novel method with a 1.6-4.5 MHz phased array probe to observe diaphragmatic movement cranio-caudally along the mid-axillary line, employing anatomic M-mode with the sampling line placed perpendicular to the diaphragm at the level of the renal midpoint, and the DE of the hepato-renal/spleno-renal section was measured during normal breathing. The liver and hepato-renal sections were used to assess the right diaphragm, and spleen and spleno-renal sections were used to assess the left diaphragm. Correlation analysis of DE measurements from different sections was conducted using the Deming method, while consistency was assessed using the Bland-Altman method. The consistency of clinical acceptability was defined as the absence of fixed and proportional bias, with a difference of two standard deviations less than 40% of the mean measurement value. Percentage consistency limit = two standard deviations of the differences between measurements/mean measurement value×100%.Four operators performed image scans of DE in all four sections for each of the twelve subjects, with a high DE acquisition rate of 100% (48/48) for hepato-renal and spleno-renal sections, followed by the liver section [91.7% (44/48)] and the spleen section [66.7% (32/48)], particularly for the left diaphragm assessment, where the DE acquisition rate of spleno-renal section was significantly higher than that of traditional spleen section (P 0.05), and they were significantly higher than those determined via the conventional liver and spleen sections (cm: hepato-renal section vs. liver section was 1.64±0.10 vs. 1.44±0.09, spleno-renal section vs. spleen section was 1.55±0.14 vs. 1.09±0.14, both P 40%). There was no statistically significant difference in DE measured by the four operators in the liver, spleen, hepato-renal, and spleno-renal sections (cm: 1.49±0.34, 1.44±0.37, 1.43±0.30, and 1.40±0.27 in liver section; 1.10±0.36, 1.05±0.18, 1.09±0.22, and 1.06±0.26 in spleen section; 1.67±0.43, 1.57±0.34, 1.63±0.32, and 1.66±0.36 in hepato-renal section; 1.45±0.33, 1.48±0.34, 1.50±0.24, and 1.65±0.26 in spleno-renal section; all P > 0.05). According to the clinically acceptable range of consistency limits, the DE measured by the four operators in all four sections showed good consistency (all % consistency limits < 40%).The novel method of measuring DE through hepato-renal/spleno-renal sections is accurate, highly reproducible, and has a high acquisition rate, serving as a viable alternative to the conventional method involving the liver/spleen section.

Related Organizations
Keywords

Adult, Male, Young Adult, Liver, Diaphragm, Humans, Reproducibility of Results, Female, Kidney, Spleen, Ultrasonography

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!