Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Rebound tonometry with sterilized probes].

Authors: Daniel M, Handzel; C, Ben Abdallah; H, Habie; A, Alani; W, Sekundo;

[Rebound tonometry with sterilized probes].

Abstract

Intraoperative measurement of intraocular pressure (IOP) opens up possibilities to investigate the influence of IOP on the stability of the eyeball during the performance of surgical maneuvers. Few techniques have been described, none of which are commercially available. This study investigated the use of sterilized probes for rebound tonometry, which could be used intraoperatively.Tonometry was performed on 30 eyes using a noncontact tonometer and rebound tonometry with the iCare 100 and iCare 200 (iCare Finland Oy, Vantaa, Finland) in a sitting and in a supine position. When performing rebound tonometry probes from the package were used sequentially with sterilized probes. The comparability of sterilized and nonsterilized probes was investigated using different rebound tonometers and different settings.Measurements on a sitting subject were comparable with sterilized and nonsterilized probes. Statistically significant comparability was also found in a supine position. Measurements with identically sterilized probes on identically positioned subjects were comparable with iCare 100 und iCare 200 (T2 vs. T4, p = 0.003 und T3 vs. T5 p < 0.001). The comparison of measurements of the original probe with the sterilized probe in a sitting and in a supine position were possible with statistical significance (p < 0.005). Measuring with the iCare 200 in a sitting position showed a slightly lower IOP with the sterilized probe with the difference being statistically significant.Single autoclaving does not alter the probes' ability to measure IOP.The use of probes which have been sterilized according to the regulations for other surgical instruments opens up new possibilities for the intraoperative measurement of IOP. This facilitates the use in scientific studies on surgical techniques. In the postoperative period the use of sterilized probes can reduce the risk of infection.

Related Organizations
Keywords

Tonometry, Ocular, Manometry, Humans, Reproducibility of Results, Glaucoma, Intraocular Pressure

  • BIP!
    Impact byBIP!
    citations
    The total number of citations received by all articles of the researcher of interest.
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
The total number of citations received by all articles of the researcher of interest.
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!