Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Diagnostic significance of late ventricular potentials].

Authors: A, Lautsiavichius; G, Braĭtkhardt; G, Uzhdavinis; U, Karben; N, Paliushinskaia;

[Diagnostic significance of late ventricular potentials].

Abstract

A study using two methods of noninvasive registration of ventricular late potentials (VLP), computer averaging and beat-to-beat spatial averaging, was conducted in 27 patients with ventricular tachycardia and 11 healthy volunteers. Both techniques are described in detail. The duration of QRS complex on high resolution ECG was found to be significantly longer in patients with VLP as compared to those of patients without VLP and having ventricular tachycardia as well as healthy adults. The data obtained by both methods do not differ significantly. The beat-to-beat method was not informative in about 20% of cases because of the ineffective filtering procedure and the presence of myographic noise on the amplified CS. The duration of VLP was 44 +/- 20 ms in patients with documented ventricular tachycardia. The sensitivity of the assessment of arrhythmogenic ventricular activity was 70% with the computer method, and 59% with the beat-to-beat spatial averaging technique. The specificity and predictive value of both registration methods were 100%.

Keywords

Adult, Male, Time Factors, Computers, Action Potentials, Middle Aged, Electrocardiography, Evaluation Studies as Topic, Heart Conduction System, Ventricular Fibrillation, Humans, Female, Tachycardia, Paroxysmal, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!