[Analysis of intraoperative EABR characteristics and postoperative efficacy of cochlear implant in patients with tinnitus].

Authors: Xiaohui, Guo; Bin, Wang; Keli, Cao; Zhiqiang, Gao; Chaogang, Wei;

[Analysis of intraoperative EABR characteristics and postoperative efficacy of cochlear implant in patients with tinnitus].

Abstract

Objective:To investigate the characteristics of intraoperative electrically stimulated auditory brainstem responses(EABR) in patients with neural deafness and tinnitus, and to analyze the inhibitory effect of cochlear implantation on tinnitus and its correlation with auditory evoked potential. Methods:Twenty-eight adult patients with neuronal deafness accompanied by tinnitus who underwent cochlear implant surgery in the Peking Union Medical College Hospital from 2014 to 2015 were selected, and 10 age-matched patients without tinnitus with the same age were selected as the control group. Preoperative audiology, imaging and tinnitus history of the patients were retrospectively analyzed. During the operation, EABR were used to detect the auditory central functions at all levels, and the electrophysiological characteristics of the two groups were analyzed. The tinnitus handicap inventory(THI) was used to evaluate the severity of tinnitus before and after surgery, and the correlation between EABR results and THI score was analyzed. Results:There were no postoperative complications such as facial paralysis, cerebrospinal fluid leakage, meningitis, etc. , and electroacoustic reactions were observed in all 38 patients. The results of intraoperative EABR showed that there were significant differences in Ⅲ wave amplitude, Ⅴ wave amplitude and Ⅴ wave latency between tinnitus group and control group(P0.05). There was significant correlation between the intraoperative EABR wave Ⅲ amplitude and the linear correlation analysis of THI changes 1 year after operation(r=0.873, P<0.05). Conclusion:There is significant difference in intraoperative EABR between patients with neural deafness accompanied with tinnitus and patients without tinnitus. Cochlear electrical stimulation has a good inhibitory effect on tinnitus, and intraoperative EABR can be used as a objective assessment tool for cochlear implant to inhibit tinnitus.

Related Organizations
Keywords

Adult, Tinnitus, Cochlear Implants, Humans, Deafness, Cochlear Implantation, Retrospective Studies

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!