Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Validation of a rapid and economical RP-HPLC method for simultaneous determination of metformin hydrochloride and sitagliptin phosphate monohydrate: Greenness evaluation using AGREE score.

Authors: Aqeela, Raza; Syed Hassan, Murtaza; Sana, Hanif; Javed, Iqbal; Ijaz, Ali; Tayyaba, Aftab; Rouheena, Shakir; +2 Authors

Validation of a rapid and economical RP-HPLC method for simultaneous determination of metformin hydrochloride and sitagliptin phosphate monohydrate: Greenness evaluation using AGREE score.

Abstract

Reported high performance liquid chromatographic (HPLC) methods for estimating metformin hydrochloride (MET) and sitagliptin phosphate monohydrate (SIT) are either laborious or contain higher proportions of organic solvents in mobile phase, thus presenting exorbitant procedures. So, a rapid, significantly more economical and eco-friendly HPLC method for synchronized analysis of both drugs was aimed to develop and validate in current study. Analytical evaluation was executed on Shimadzou⌖ C18 column (250mm × 4.6mm, 5μm) using acidified water and methanol 60:40 (v/v) as mobile phase at a flow of 1mL/min; while peaks were detected at 260nm at 25°C. Resultant values of accuracy, precision, linearity, limit of detection (LOD), limit of quantification (LOQ), robustness and specificity depicted that the method was validated in accordance with the ICH Guidelines. The approximate retention time for MET and SIT were 1.96 and 3.70 min, correspondingly. The greenness score of the developed method was evaluated using AGREE software and was found better (0.81) as compared with the methods reported (<0.8). Conclusively, the developed method was time saving, economical, rapid, robust, rugged, precise, accurate and found to be applicable for simultaneous determination of MET and SIT in commercial tablets.

Related Organizations
Keywords

Limit of Detection, Sitagliptin Phosphate, Hypoglycemic Agents, Reproducibility of Results, Green Chemistry Technology, Chromatography, High Pressure Liquid, Metformin, Software

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!