Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Duplex scanning of the portal vein and portasystemic shunts.

Authors: N, Ackroyd; R, Gill; K, Griffiths; G, Kossoff; T, Reeve;

Duplex scanning of the portal vein and portasystemic shunts.

Abstract

This article describes the preliminary findings of a Duplex ultrasound technique that enables the patency of the portal circulation and portosystemic shunt patency to be determined. In addition, the equipment allows the noninvasive measurement of quantitative rates of blood flow in these vessels. Portal vein flow was 952 +/- 273 ml/min in 10 normal subjects after an overnight fast and increased by 50% at 30 minutes in response to a standard 660-calorie liquid meal. Thirteen portosystemic shunts were scanned, and hemodynamic information was obtained from 10. Three of the four patients who had a Warren shunt performed 3 to 4 years earlier had portal vein occlusion. There is evidence of an increase in flow through the Warren shunt on feeding, suggesting a hemodynamic connection to the mesenteric side of the circulation. The apparatus, technique of examination, and the characteristics and difficulties with particular types of shunts are described.

Keywords

Adult, Male, Portal Vein, Hemodynamics, Humans, Portasystemic Shunt, Surgical, Female, Middle Aged, Blood Flow Velocity, Aged, Ultrasonography

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    30
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
30
Average
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!