Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Comparison of whole blood indium and the serum indium of the population exposed to the indium].

Authors: Z, Min; K P, Ma; Y F, Ke; G Y, Zhang; H Y, Zhao; D Y, Sun;

[Comparison of whole blood indium and the serum indium of the population exposed to the indium].

Abstract

Objective: The method was established for the detection of whole blood indium and serum indium. By comparing the results of two samples, it is possible to explore the significance of whole blood indium and serum indium in the population exposed to indium compounds. Methods: According to GBZ/T 295-2017 and GBZ 294-2017, the whole blood and serum samples were diluted 20 times by 0.5% nitric acid solution (including 0.05% Triton X-100) . Under the standard mode of inductively coupled plasma mass spectrometry (ICP-MS) , whole blood indium and serum indium of indirect exposure group, low exposure group and high exposure group in an indium mine were detected with 20 μg/L rhodium standard solution as internal standard. Results: This method has a working range of 0.00~5.00 μg/L and a correlation coefficien t>0.999. The detection limit and quantitative lower limit of whole blood indium were 0.076 μg/L and 0.26 μg/L respectively. Those of serum indium were 0.06 μg/L and 0.20 μg/L accordingly. The recovery rates of serum and whole blood samples were 88.5%~95.6% and 93.0%~101%. Intra batch precisions were 1.3%~4.4% and 1.9%~3.5% and inter batch precision were 2.4%~6.1% and 2.1%~4.6% in two samples. There were no significant differences between whole blood indium and serum indium in indirect exposure group. The serum indium level was lower than the detection limit in 3 cases, while their whole blood indium was only below the quantitative lower limit. However, in other groups whole blood indium level was significantly higher than serum indium level (P<0.05) and even was two-fold in the high exposure group. Conclusion: The detection of whole blood indium is more sensitive than that of serum indium, which can reflect the internal exposure level more accurately in exposure population. Therefore, the whole blood indium is of more important referential value to health examination and poisoning diagnosis in the population exposed to indium and its compounds.

Related Organizations
Keywords

Serum, Limit of Detection, Reference Values, Occupational Exposure, Humans, Indium, Blood Chemical Analysis, Mass Spectrometry

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!