The results of measurements on an Alderson phantom, as well as in-vivo-measurements, on five patients during total body irradiation are described. They were compared with computer-predicted values using the lateral A.P./P.A. irradiation, as used in Tübingen; measurements were carried out by a TLD method. Particular attention was paid to the critical areas such as the head, the neck and the lungs. The results in general agreed to within 5% and were in good accord with international findings.
Radiation Monitoring, Methods, Humans, Radiation Dosage, Whole-Body Irradiation
Radiation Monitoring, Methods, Humans, Radiation Dosage, Whole-Body Irradiation
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |