Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Smartphone-based colorimetric detection of glutathione.

Authors: Irena, Vobornikova; Miroslav, Pohanka;

Smartphone-based colorimetric detection of glutathione.

Abstract

Glutathione belongs to the family of small-molecular weight antioxidants like ascorbic acid, cysteine, α-tocopherol, uric acid, etc. These molecules play important role in the neutralization of free radicals and reactive oxygen species (ROS). Oxidative stress may lead to ageing and the development of large scale of pathological states of organism. This low molecular weight antioxidant´s level can alter under pathological conditions from reduced (GSH, thiols) to oxidized (oxidized glutathione -GSSG, disulfides) form. A GSSG-to-GSH ratio is indicative marker of oxidative stress. There is a large scale of methods how to determine this biomarker. The trend of the analysis is to minimalize the instrument equipment, sample application volume and analysis cost.Reduced glutathione (GSH) solutions were prepared in water in the concentration 0-16 mmol/L. Other small-molecular weight antioxidants like 0.25 mmol/L ascorbic acid, 0.15 mmol/L TROLOX and 0.02 mmol/L N-acetyl-cysteine (NAcCys) were studied as possible interferents. The samples were mixed with 5,5´-dithiobis-(2-nitrobenzoic) acid (DTNB) resulting in yellow colored drops forming. Coloration was assayed using camera integrated in a smartphone and color channels analysis. The total volume of 10 µl of sample was applied for one analysis. The smartphone-based data were compared with the reference Ellman assay.The calibration of glutathione was evaluated. The blue channel intensity data were decreasing according to the increasing glutathione concentration. Red and green channel intensities were stagnating during the whole concentration scale of glutathione. Limits of detection were 0.4 mmol/l for glutathione. Addition of 0.25 mmol/L of ascorbic acid, 0.15 mmol/L of TROLOX and 0.02mmol/L of N-acetylcysteine to GSH in final concentration 0-16 mmol/L had minimal influence on the assay. The results from smartphone-based analysis correlate with the standard Ellman method. The detection limit for GSH was 0.03 mmol/L.The smartphone-based assay seems to be promising because of simplicity, reliability, robustness and low cost. In spite of the fact that there is a large scale for approaches for the glutathione determination, the main advantage of our colorimetric method is portability and easibility to perform the assay in the field and publically availability of smartphones for home applications.

Related Organizations
Keywords

Humans, Biological Assay, Colorimetry, Dithionitrobenzoic Acid, Smartphone, Glutathione, Antioxidants, Biomarkers

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    2
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
2
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!