Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Pain Physicianarrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Pain Physician
Article . 2016
Data sources: Pure Amsterdam UMC
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
versions View all 3 versions
addClaim

Pain Pressure Threshold in the Region of the Sacroiliac Joint in Patients Diagnosed with Sacroiliac Joint Pain.

Authors: van Leeuwen, Robbert J. H.; Szadek, Karolina; de Vet, Henrica; Zuurmond, Wouter; Perez, Roberto;

Pain Pressure Threshold in the Region of the Sacroiliac Joint in Patients Diagnosed with Sacroiliac Joint Pain.

Abstract

Although the prevalence of sacroiliac joint (SIJ) pain is relatively high (15 - 30%), there is no unambiguous reference standard to diagnose SIJ pain. Pressure tenderness in the SIJ region is used for diagnostic purposes, but the clinimetric properties of this procedure remain to be determined.The aim of this study is to determine the reliability of pain pressure threshold (PPT) measurements in the SIJ region and the difference in PPTs in the SIJ region between healthy volunteers and PPTs in patients with SIJ pain.Prospective cohort study.Outpatient pain clinic VU University Medical Center.Forty-one healthy volunteers and 31 patients diagnosed with SIJ pain were included. PPTs were obtained from 5 measurement points in the region of the SIJ with a pressure pain algometer using a standardized protocol. The inter-rater reliability of this method was calculated by means of the Intraclass Correlation Coefficients (ICC) of individual assessment performed by 2 individual raters of SIJs of healthy volunteers on both sides. PPTs of healthy volunteers were compared to those of the affected side in patients with SIJ pain.PPT measurement showed moderate to good inter-rater reliability (ICC 0.6 - 0.82).The median PPTs of 5 points was comparable for both sides in healthy volunteers (right: 8.5 kg/cm2 [IQR 6.0 - 10.0]; left 8.3 kg/cm2 (5.8 - 10.0]). Median PPTs for the affected sides of patients with SIJ pain were significantly lower compared to the same side of healthy volunteers (right: 2.4 kg/cm2 [IQR 2.2 - 3.2, n = 15]; left: 2.5 kg/cm2 [2.3 - 3.2, n = 16]; P < 0.001 for both sides).Only the SIJ on one side of was measured in patients with SIJ pain, where both sides would be desirable.Pressure pain algometry appears to be a reliable method to establish differences in PPTs between healthy volunteers and patients with SIJ pain. The diagnostic accuracy of this test should be investigated further.

Country
Netherlands
Keywords

Adult, Male, Pain Threshold, pain pressure threshold, Sacroiliac joint pain, Sacroiliac Joint, Middle Aged, Arthralgia, Cohort Studies, Pressure, Humans, Female, Prospective Studies, Low Back Pain, pressure algometry, Pain Measurement

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    6
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
6
Average
Average
Average
gold