Galvanoceramic restorations were constructed for five extracted teeth. Following cementation, the margins were photographed (magnification X 33) and the prints mounted to produce a continuous image of the entire margin. Cement film thickness measurements were made at 0.1-mm intervals. The five cemented restorations were then embedded in resin, sectioned longitudinally, and examined under a microscope (X 125). The mean gap at the restoration margin, as measured by each technique, was 18 microns and 19 microns, respectively. These results were consistent with the clinical impressions of cemented galvanoceramic restorations completed at the University of Tübingen.
Crowns, Dental Bonding, Humans, Denture Design, Electrolysis
Crowns, Dental Bonding, Humans, Denture Design, Electrolysis
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 6 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |