Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Phacoemulsification systems.

Phacoemulsification systems.

Abstract

Our objectives in conducting this evaluation were to present an overview of a basic phacoemulsification system and its components, to describe the phacoemulsification procedure within the context of the operating principles of the system's components, and to compare two manufacturers' products. Specifications for additional phacoemulsification systems are available in the November 1989 edition of ECRI's Hospital Product Comparison System. Both of the evaluated systems enable a surgeon to perform a complete cataract extraction procedure by phacoemulsification. We rated both units Acceptable. In selecting a unit, users should consider performance, safety, human factors design, and manufacturer training and support. Although list prices vary widely among available systems, cost factors should not override clinical performance and safety requirements. While we measured certain engineering parameters, such as stroke length and ultrasound (US) output forces exerted on a medium, we stress that the results of these tests do not provide enough information to predict clinical performance. Clinical performance of phacoemulsification systems can be determined only by the experience of the clinicians who use them. Clinicians should review our evaluation thoroughly before making a purchasing decision. The information we present is useful for purchasing the evaluated or other available models because our criteria will guide users in assessing all components, and our findings and discussion on some aspects are common to many available systems (e.g., type of pump, irrigation and aspiration [I/A] characteristics). The in-depth clinical and technical information will help users to better understand principles, thereby helping them to better define their needs. Although we discovered a number of problems with the evaluated models, users should not assume that similar or other problems do not exist with systems that we did not evaluate. The willingness of manufacturers to cooperate in our studies and the knowledge they gain through participating may lead to the development of better products.

Keywords

Lenses, Intraocular, Electric Wiring, Technology Assessment, Biomedical, Equipment Safety, Evaluation Studies as Topic, Ultrasonic Therapy, Humans, Cataract Extraction, Ergonomics, Hyaluronic Acid, Suction

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Related to Research communities
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!