Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Experience with dilatation of tight esophageal stenoses using a balloon catheter].

Authors: J, Bohutová; J, Kolár;

[Experience with dilatation of tight esophageal stenoses using a balloon catheter].

Abstract

The dilatation of oesophageal stenoses with balloon catheters was made in 38 patients with 44 stenoses of different origin. The most frequent stenosis was localized in oesophagogastric or oesophagocolic anastomosis after oesophagectomy, postcorrosive stenoses an those after reflux oesophagitis. The stenoses were mostly of filiform type, the diameter being 1-3 mm (79%) less frequently 4-7 mm (21%). It became possible to dilate 37 stenoses up to 10 to 20 mm, four stenoses to 22 mm. In only three cases the stenosis was dilated to less than 10 mm. In six patients it proved necessary to repeat the dilatation within one to six-month intervals. The dilatation failed to give positive in one case.

Keywords

Adult, Aged, 80 and over, Male, Radiography, Esophageal Stenosis, Humans, Female, Middle Aged, Aged, Catheterization

  • BIP!
    Impact byBIP!
    citations
    The total number of citations received by all articles of the researcher of interest.
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
The total number of citations received by all articles of the researcher of interest.
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!