PURPOSE: To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneities METHODS: Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subjects acquired with both 1.5T and 3.0T whole-body MRI. (ii) Seven liver tissue ROIs from 36 patients imaged using 1.5T MRI at six time points after Gd-EOB-DTPA injection. The performance of CIIC was evaluated quantitatively by analyzing its impact on the dispersion and bias of the water image ROI intensities, and qualitatively using side-by-side image comparisons. RESULTS: CIIC significantly ( P1.5T≤2.3×10-4,P3.0T≤1.0×10-6) decreased the nonphysiological intensity variance while preserving the average intensity levels. The side-by-side comparisons showed improved intensity consistency ( Pint≤10-6) while not introducing artifacts ( Part=0.024) nor changed appearances ( Papp≤10-6). CONCLUSION: CIIC improves the spatiotemporal intensity consistency in regions of a homogenous tissue type. J. Magn. Reson. Imaging 2014.
Funding:Financial support from the Swedish Research Council (VR/M 2007-2884), the Research Council of Southeast Sweden (FORSS 12621), Linkoping University, Lions Research Foundation in Linkoping, Linkoping University Hospital Research Foundations and the County Council of Ostergotland is gratefully acknowledged.
Adult, Male, Reproducibility of Results, Signal Processing, Computer-Assisted, Image Enhancement, Magnetic Resonance Imaging, Sensitivity and Specificity, Medical Imaging, Imaging, Three-Dimensional, Medicinsk bildvetenskap, Adipose Tissue, Body Water, Subtraction Technique, Image Interpretation, Computer-Assisted, Humans, Radiologi och bildbehandling, Artifacts, Muscle, Skeletal, water–fat imaging;Dixon imaging;inhomogeneity correction;intensity correction;water;fat quantification, Radiology, Nuclear Medicine and Medical Imaging
Adult, Male, Reproducibility of Results, Signal Processing, Computer-Assisted, Image Enhancement, Magnetic Resonance Imaging, Sensitivity and Specificity, Medical Imaging, Imaging, Three-Dimensional, Medicinsk bildvetenskap, Adipose Tissue, Body Water, Subtraction Technique, Image Interpretation, Computer-Assisted, Humans, Radiologi och bildbehandling, Artifacts, Muscle, Skeletal, water–fat imaging;Dixon imaging;inhomogeneity correction;intensity correction;water;fat quantification, Radiology, Nuclear Medicine and Medical Imaging
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 29 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |