Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ http://dx.doi.org/10...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 2 versions
addClaim

MPFL reconstruction using a quadriceps tendon graft: part 1: biomechanical properties of quadriceps tendon MPFL reconstruction in comparison to the Intact MPFL. A human cadaveric study.

Authors: Herbort, Mirco; Hoser, Christian; Domnick, Christoph; Raschke, Michael J.; Lenschow, Simon; Weimann, Andre; Kösters, Clemens; +1 Authors

MPFL reconstruction using a quadriceps tendon graft: part 1: biomechanical properties of quadriceps tendon MPFL reconstruction in comparison to the Intact MPFL. A human cadaveric study.

Abstract

The aim of this study was to analyze the structural properties of the original MPFL and to compare it to a MPFL-reconstruction-technique using a strip of quadriceps tendon.In 13 human cadaver knees the MPFLs were dissected protecting their insertion at the patellar border. The MPFL was loaded to failure after preconditioning with 10 cycles in a uniaxial testing machine evaluating stiffness, yield load and maximum load to failure. In the second part Quadriceps-MPFL-reconstruction was performed and tested in a uniaxial testing machine. Following preconditioning, the constructs were cyclically loaded 1000 times between 5 and 50 N measuring the maximum elongation. After cyclic testing, the constructs have been loaded to failure measuring stiffness, yield load and maximum load. For statistical analysis a repeated measures (RM) one-way ANOVA for multiple comparisons was used. The significance was set at P<0.05.During the load to failure tests of the original MPFL the following results were measured: stiffness 29.4 N/mm (+9.8), yield load 167.8 N (+80) and maximum load to failure 190.7 N (+82.8). The results in the QT-technique group were as follows: maximum elongation after 1000 cycles 2.1 mm (+0.8), stiffness 33.6 N/mm (+6.8), yield load 147.1 N (+65.1) and maximum load to failure 205 N (+77.8). There were no significant differences in all tested parameters.In a human cadaveric model using a strip of quadriceps-tendon 10 mm wide and 3mm deep, the biomechanical properties match those of the original MPFL when tested as a reconstruction.The tested QT-technique shows sufficient primary stability with comparable biomechanical parameters to the intact MPFL.

Related Organizations
Keywords

Joint Instability, MPFL, Dissection, Middle Aged, Stiffness, Arthroplasty, Quadriceps Muscle, Tendons, Weight-Bearing, Patellofemoral Joint, Quadriceps tendon reconstruction, Ligaments, Articular, Cadaver, Humans, Knee, Biomechanics, Range of Motion, Articular, Aged

  • BIP!
    Impact byBIP!
    citations
    The total number of citations received by all articles of the researcher of interest.
    55
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
The total number of citations received by all articles of the researcher of interest.
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
55
Top 10%
Top 10%
Top 10%