Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Simultaneous determination of chlorhexidine acetate and benzalkonium chloride in compound chemical disinfectants by capillary electrophoresis].

Authors: Baohua, Song; Xiaojing, Ding; Jia, Li; Zhi, Wang;

[Simultaneous determination of chlorhexidine acetate and benzalkonium chloride in compound chemical disinfectants by capillary electrophoresis].

Abstract

Benzalkonium chloride (BAC) is a mixture of alkyl substituted benzyl dimethylammonium chloride homologs (C12-BAC, C14-BAC and C16-BAC). Chlorhexidine acetate is a widely used effective component in compound chemical disinfectants. A method for the simultaneous determination of chlorhexidine acetate and benzalkonium chloride in compound chemical disinfectants by capillary electrophoresis (CE) was established. The CE analysis was carried out using an uncoated capillary with 50 microm i. d. and 37 cm total length. The running buffer was 150 mmol/L NaH2PO4-62.5 mmol/L H3PO4 (pH 2.5) containing 40% (v/v) acetonitrile. The sample medium was 50 mmol/L acetic acid-acetonitrile (1:1, v/v). The detection wavelength was 214 nm. The factors such as the buffer concentration and pH, the content of acetonitrile, which influenced the separation and accurate assay of compound chemical disinfectants were investigated in detail. The intra-day and inter-day precisions of the method were below 3. 0% and 3.7%, respectively. The limits of detection (LOD, signal to noise ratio (S/N) = 3) for chlorhexidine acetate, C12-BAC, Cl4-BAC and C16-BAC were 0. 3, 0.5, 0.5 and 0.5 mg/L, respectively. The limits of quantification (LOQ, S/N = 10) were 1.0, 1.5, 1.5, and 1.5 mg/L, respectively. The corrected peak area and the mass concentration of the four components mentioned above showed good linear relationships within the ranges of 1.0 - 400 mg/L, 1. 5 - 200 mg/L, 1.5 - 200 mg/L and 1.5 - 200 mg/L, with linear correlation coefficients (r) of 0.9995, 0.9998, 0.999 7 and 0.9998, respectively. The established method was used for the determination of the four disinfectants in the compound chemical disinfectants. The results were in good agreement with those obtained by the high performance liquid chromatographic method.

Related Organizations
Keywords

Chlorhexidine, Electrophoresis, Capillary, Benzalkonium Compounds, Disinfectants

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    2
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
2
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!