Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Ultrasonography in the hyperhydrated patient].

Authors: Michele, Prencipe; Alessandro, D'Amelio; Filippo, Aucella; Antonio, Granata; Fulvio, Fiorini;

[Ultrasonography in the hyperhydrated patient].

Abstract

The achievement of a normal hydration state is one of the major targets of hemodialysis. It is based on the estimation of ''dry weight'', which corresponds to the normal body fluid content. Even though the concept of dry weight in hemodialysis patients is clinically undisputed, it is not always easy to achieve in this population. Assessment of the hydration state by clinical examination is imprecise and often unreliable. Measurement of the inferior vena cava (IVC) diameter has been shown to reflect individual fluid status. The relationship between the variation of the IVC diameter before and after the hemodialysis session and weight loss has been investigated. Measurement of the IVC diameter by ultrasound is considered a valid measure of the hydration state and can be routinely used in hemodialysis patients. Moreover, a relationship between IVC diameter, respiratory activity and the hydration state, evaluated by considering both plasma volume and central venous pressure, has been demonstrated. In conclusion, assessment of the hydration state based on blood pressure and central venous pressure can be considered reliable only in patients without signs of heart failure.

Keywords

Body Water, Renal Dialysis, Humans, Ultrasonography

  • BIP!
    Impact byBIP!
    citations
    The total number of citations received by all articles of the researcher of interest.
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
The total number of citations received by all articles of the researcher of interest.
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!