Dosimetric verification of biologically adapted IMRT.

Authors: Jan, Rødal; Einar, Waldeland; Aste, Søvik; Eirik, Malinen;

Dosimetric verification of biologically adapted IMRT.

Abstract

To investigate the delivery of biologically adapted high resolution intensity modulated radiotherapy (IMRT) to an anthropomorphic phantom, using dosimetric and radiobiologic measures.A compartment based 3D hypoxia map of a highly heterogeneous tumor was imported into the CT planning basis of an anthropomorphic phantom. Biologically adapted IMRT was planned according to the corresponding 3D dose prescription map with elevated dose to the hypoxic regions. Three treatment fractions were delivered to the phantom by means of a conventional linear accelerator equipped with a high resolution micro multileaf collimator (mMLC). EDR2 radiographic films were positioned in two planes of the phantom during irradiation. Software was developed to analyze dose distributions from the prescription, dose plan, and films. Dose distributions were scored within each of four radiobiologic tumor compartments. The treatment effect in each tumor compartment was estimated as the equivalent uniform dose (EUD). A conventional gamma analysis was utilized for quantitative comparisons of planned and delivered dose distributions.The planned and delivered dose maps qualitatively resembled the prescribed dose map. The gamma analyzes showed that, on average for all films, more than 95% of the pixels within the tumor passed the 3%/2 mm criteria. For compartments with increasing degree of hypoxia and thereby increased prescribed dose, the planned and delivered EUDs were severely reduced compared to the prescription. The prescribed compartmental doses were met only for the most oxic compartment. The mean tumor dose as measured by the films was 6.6% lower than the corresponding planned dose.Biologically adapted radiotherapy may be delivered with high precision according to the dose plan. However, the large reduction in compartmental EUD values from prescribed to planned treatment indicated lower tumor effect than expected for such a treatment.

Related Organizations
Keywords

Treatment Outcome, Neoplasms, Humans, Biological Assay, Radiotherapy Dosage, Radiotherapy, Conformal, Adaptation, Physiological, Radiotherapy, Computer-Assisted, Feedback

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    1
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
1
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!