Phase-contrast (PC) edge enhancement occurs at the boundary between different tissues and is an interference effect that results from the differential phase-shifts that the x-rays acquire while traversing the two tissues. While observable in planar phase-contrast radiographs, the impact of digital tomosynthesis on this edge enhancement effect has not been previously reported. The purpose of this work is to demonstrate: (1) that phase-contrast digital tomosynthesis (PC-DTS) is possible with a conventional x-ray source, (2) that the reconstructed tomosynthesis images demonstrate and retain edge enhancement as compared to planar phase-contrast radiographs and (3) tomosynthesis improves object contrast by reducing the effects of superimposed structures.An unmodified, commercially available cabinet x-ray system (Faxitron LX-60) was used. The system contains a tungsten anode x-ray tube that was operated at 24 kVp and 3 mAs for each PC radiographic image taken, with a nominal focal spot size of 0.010 mm. The digital detector uses CsI/CMOS with a pixel size of 0.054 mm x 0.054 mm. Objects to be imaged were attached to a computer-controlled rotating motor and are rotated +/- 25 degrees about a central position in one degree increments. At each increment, three phase-contrast radiographs are taken and then averaged to reduce the effect of noise. These planar images are then used to reconstruct a series of 56 longitudinal tomographic images with an image offset increment of about 0.7 mm.Tomographic z-plane resolution was measured to be approximately 4 mm. When compared to planar PC images, the tomosynthesis images were shown to retain the PC boundary edge enhancement in addition to an improvement in object contrast.Our work demonstrates that PC digital tomosynthesis retains the edge-enhancement observed in planar PC radiograph and further improves soft-tissue conspicuity by reducing the effects of superimposed tissue structure.
Equipment Failure Analysis, Radiographic Image Enhancement, Image Interpretation, Computer-Assisted, Reproducibility of Results, Equipment Design, Image Enhancement, Tomography, X-Ray Computed, Sensitivity and Specificity, Algorithms
Equipment Failure Analysis, Radiographic Image Enhancement, Image Interpretation, Computer-Assisted, Reproducibility of Results, Equipment Design, Image Enhancement, Tomography, X-Ray Computed, Sensitivity and Specificity, Algorithms
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 18 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |