Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Recolector de Cienci...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 1 versions
addClaim

Automatización de ensayos de robustez eléctrica (Normativa VW80.000)

Authors: Bargalló Gil, David;

Automatización de ensayos de robustez eléctrica (Normativa VW80.000)

Abstract

Aquest projecte es va desenvolupar al Test Center Energy de SEAT S.A., centrat en l’automatització dels assaigs de robustesa elèctrica conforme a la normativa VW80.000, aplicada a la xarxa de bord de 12V de les bateries d’alta tensió. La manca d'equips adequats i els alts costos limitaven l'eficiència operativa, ja que moltes proves es realitzaven manualment o es subcontractaven. L'objectiu del projecte va ser dissenyar i fabricar un nou equip, Robusbatt 80.000, que realitza aquests assaigs a un cost inferior al del PFM 200N Series, i opera de manera paral·lela amb aquest. L’equip consta d’una placa PCB amb un microcontrolador per a la comunicació CAN, cosa que permet una execució automatitzada i eficient de les proves. Com a resultat, es va aconseguir un prototip més econòmic que augmenta la capacitat operativa del TCE.

Este proyecto se desarrolló en el Test Center Energy de SEAT S.A., centrado en la automatización de los ensayos de robustez eléctrica conforme a la normativa VW80.000, aplicada a la red de a bordo de 12V de las baterías de alta tensión. La falta de equipos adecuados y los altos costos limitaban la eficiencia operativa, ya que muchas pruebas se realizaban manualmente o se subcontrataban. El objetivo del proyecto fue diseñar y fabricar un nuevo equipo, Robusbatt 80.000, que realiza estos ensayos a menor costo que el PFM 200N Series, y opera de manera paralela con este. El equipo consta de una placa PCB con un microcontrolador para comunicación CAN, permitiendo una ejecución automatizada y eficiente de las pruebas. Como resultado, se logró un prototipo más económico que aumenta la capacidad operativa del TCE.

This project was developed at SEAT S.A.'s Test Center Energy, focused on automating electrical robustness tests in accordance with the VW80.000 standard, applied to the 12V onboard network of high-voltage batteries. The lack of suitable equipment and high costs limited operational efficiency, as many tests were performed manually or outsourced. The goal of the project was to design and manufacture a new device, Robusbatt 80.000, which performs these tests at a lower cost than the PFM 200N Series and operates in parallel with it. The device consists of a PCB board with a microcontroller for CAN communication, allowing for an automated and efficient execution of the tests. As a result, a more cost-effective prototype was achieved, increasing the operational capacity of the TCE.

Country
Spain
Keywords

Automatización, PCB, Red de a bordo de 12V, Robust control, Prototipo, Control de robustesa, Microcontrolador, Normativa VW80.000, SEAT S.A, 620, SEAT S.A., Test Center Energy, Ensayos de robustez eléctrica, Àrees temàtiques de la UPC::Informàtica::Automàtica i control, Baterías de alta tensión, Àrees temàtiques de la UPC::Enginyeria electrònica, Comunicación CAN

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 27
    download downloads 14
  • 27
    views
    14
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
0
Average
Average
Average
27
14
Green