The study aimed to study the accuracy in RR time series derived from the seismocardiogram when employing different heartbeat detectors in subjects measured in a quiet environment. The ECG and seismocardiogram of 17 healthy volunteers was recorded at a sampling frequency of 5 kHz using a Biopac acquisition system. The seismocardiogram was acquired using a triaxial accelerometer (LIS344ALH, ST Microelectronics). Four detectors of the heartbeat from the seismocardiogram were employed relying either on the Continuous Wavelet Transform or bandpass filtering. The detectors adapt their parameters to the morphology of the signal by estimating mean heart rate and the bandwidth of the signal associated to the heartbeat. For all detectors, the standard deviation of the error in the obtained RR time series is in mean slightly higher than 2 ms and the percentage of obtained RR time intervals that have an error higher than 30 ms is around 3.5%. The seismocardiogram, when measured in a quiet environment, can be used instead of the ECG to obtain reliable RR time series when using proper heartbeat detectors.
Peer Reviewed
:Ciències de la salut::Medicina [Àrees temàtiques de la UPC], Heart beat, Detectors, Time measurement, Àrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura, Seismic measurements, Abstracts, Ciència -- Aparells i instruments, Àrees temàtiques de la UPC::Ciències de la salut::Medicina, :Enginyeria electrònica::Instrumentació i mesura [Àrees temàtiques de la UPC], Cor -- Batecs, Scientific apparatus and instruments, Biomedical measurement
:Ciències de la salut::Medicina [Àrees temàtiques de la UPC], Heart beat, Detectors, Time measurement, Àrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura, Seismic measurements, Abstracts, Ciència -- Aparells i instruments, Àrees temàtiques de la UPC::Ciències de la salut::Medicina, :Enginyeria electrònica::Instrumentació i mesura [Àrees temàtiques de la UPC], Cor -- Batecs, Scientific apparatus and instruments, Biomedical measurement
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 70 | |
| downloads | 24 |

Views provided by UsageCounts
Downloads provided by UsageCounts