Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Torsional superelasticity of NiTi archwires.

Authors: Yves, Bolender; Anne, Vernière; Christophe, Rapin; Marie-Pierryle, Filleul;

Torsional superelasticity of NiTi archwires.

Abstract

To reproduce and compare the intraoral torsional behavior of 10 commonly used preformed upper NiTi 0.017 x 0.025 archwires in 0.018-slot brackets at 20 degrees C, 35 degrees C, and 55 degrees C.Ten upper preformed NiTi archwires were compared to a multibraided stainless steel wire. An original testing bench was used to reproduce palatal root torque applied onto an upper central incisor with a maximum value of 1540 g x mm. Ten samples of each wire type were tested at 20 degrees C, 35 degrees C, and 55 degrees C each.Loading and unloading at 20 degrees C revealed three categories of wires: a group of four NiTi wires of relative stiffness bereft of any superelasticity, a group of six NiTi wires displaying some horizontal plateau, and finally the stainless steel wire of lesser stiffness. Testing at the average oral temperature of 35 degrees C produced the same three categories of wires, with only 2 of 10 NiTi wires displaying a superelastic effect (Copper NiTi 35 degrees C and 40 degrees C). None of the NiTi wires was superelastic at 55 degrees C. Moments increased with temperature as the martensite was replaced by the more rigid austenite.This study showed that most NiTi wires did not exhibit in torsion the superelastic effect traditionally described in bending. The combination of straight-wire prescriptions and rectangular superelastic NiTi archwires did not provide optimal constant moments necessary to gain third-order control of tooth movement early in treatment. A braided stainless steel rectangular archwire displayed better torsional behavior at 35 degrees C than most NiTi archwires of the same dimensions.

Keywords

Dental Stress Analysis, Titanium, Nickel, Materials Testing, Orthodontic Wires, Temperature, Torsion, Mechanical, Stainless Steel, Copper, Elasticity, Dental Alloys

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!