Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Indian Journal of An...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Indian Journal of Anaesthesia
Article . 2009
Data sources: DOAJ
versions View all 2 versions
addClaim

Evaluation of Truview evo2 Laryngoscope In Anticipated Difficult Intubation - A Comparison To Macintosh Laryngoscope.

Authors: Ishwar Singh; Abhijit Khaund; Abhishek Gupta;

Evaluation of Truview evo2 Laryngoscope In Anticipated Difficult Intubation - A Comparison To Macintosh Laryngoscope.

Abstract

The aim of the study was to assess and compare laryngoscopic view of Truview evo2 laryngoscope with that of Macintosh laryngoscope in patients with one or more predictors of difficult intubation (PDI). Moreover ease of intubation with Truview evo2 in terms of absolute time requirement was also aimed at. Patients for elective surgery requiring endotracheal intubation were initially assessed for three PDI parameters - modified Mallampati test, thyro-mental distance & Atlanto-occipital (AO) joint extension. Patients with cumulative PDI scores of 2 to 5 (in a scale of 0 to 8) were evaluated for Cormack & Lehane (CL) grading by Macintosh blade after standard induction. Cases with CL grade of two or more were further evaluated by Truview evo2 laryngoscope and corresponding CL grades were assigned. Intubation attempted under Truview evo2 vision and time required for each successful tracheal intubation (i.e. tracheal intubation completed within one minute) was noted. Total fifty cases were studied. The CL grades assigned by Macintosh blade correlated well with the cumulative PDI scores assigned preoperatively, confirming there predictability. Truview evo2 improved laryngeal view in 92 % cases by one or more CL grade. Intubation with Truview evo2 was possible in 88% cases within stipulated time of one minute and mean time of 28.6 seconds with SD of 11.23 was reasonably quick. No significant complication like oro- pharyngeal trauma or extreme pressor response to laryngoscopy was noticed. To conclude, Truview evo2 proved to be a better tool than conventional laryngoscope in anticipated difficult situations.

Related Organizations
Keywords

Truview laryngoscope, Anesthesiology, Difficult airway, RD78.3-87.3, Macintosh laryngoscope

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    14
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
14
Average
Top 10%
Average
gold