Small diameter synthetic vascular grafts have yet to be clinically successful due to luminal narrowing from thrombosis and intimal hyperplasia. Current attempts to address this issue include the development of materials that support endothelialisation and protein modification to the material surfaces that reduce thrombosis. The extracellular matrix protein elastin has been found to be one of the least thrombogenic components of blood vessels, and its purified and recombinant forms have shown reduced thrombogenicity in both in vitro and in vivo models. Biomaterial coatings of elastin-like polypeptides (ELPs) recombinantly produced in the Woodhouse laboratory showed reduced fibrinogen adsorption, platelet adhesion, and platelet activity. However, the reason for their relative non-thrombogenicity is still not fully understood. In this work, the leukocyte response to ELP-coated materials was investigated. In particular, ELP1 and ELP4, which differ in molecular weight and sequence length, were physically adsorbed to a polyethylene terephthalate surface (MylarTM), yielding 0.22 ± 0.13 μg/cm2 and 0.37 ± 0.19 μg/cm2 surface coverage, respectively, as determined by the colorimetric assay, FastinTM Elastin. These surfaces were exposed to flowing citrated whole blood for surface and bulk evaluation of leukocyte activity using scanning electron microscopy and flow cytometry, respectively. Little leukocyte activation was observed on the surface of the controls, low-density polyethylene and uncoated MylarTM. In the bulk, tissue factor (TF) expression (monocytes: ELP1 = 38.6 ± 16.3 %, ELP4 = 33.9 ± 18.1 %) and platelet-leukocyte aggregates determined by CD61 (monocytes: ELP1 = 63.1 ± 17.1 %, ELP4 = 61.8 ± 16.8 %; granulocytes: ELP1 = 62.7 ± 17.0 %, ELP4 = 60.5 ± 20.1 %) were both decreased compared to uncoated MylarTM, while CD11b upregulation (monocytes: ELP1 = 18.7 ± 2.2 %, ELP4 = 19.7 ± 2.7 %; granulocytes: ELP = 21.4 ± 3.7 %, ELP4 = 22.0 ± 3.2 %) was increased. The statistical dependence of TF expression and platelet-monocyte aggregates was tested; however, no correlation was found. Overall, platelet-leukocyte aggregate formation was reduced and there were conflicting results with regards to the reduction of leukocyte activation for the ELP coatings on MylarTM.
cone and plate, shear rate, leukocytes, CD11b, elastin-like polypeptides, elastin, tissue factor, blood-contacting devices
cone and plate, shear rate, leukocytes, CD11b, elastin-like polypeptides, elastin, tissue factor, blood-contacting devices
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |