[Priapism of low flow].

Authors: J L, Ruiz Cerda; B, Moreno Pardo; G, Server Pastor; J M, Osca García; C, Vera Donoso; J F, Jiménez Cruz;

[Priapism of low flow].

Abstract

The results obtained after treating 13 patients with low flow priapism diagnosed by cavernous gasometry, penile ecodoppler and cavernosography are explained. Seven cases of priapism (53%) developed following intracavernous injection of vasoactive drugs and had a good response to aspiration lavage and alpha-agonist medication. None of the cases needed shunt technique to achieve detumescence and all showed good evolution with regard to the erectile function. Six cases of priapism (47%) were idiopathic and they all needed some type of venous by-pass. Later, only one had normal erections.

Related Organizations
Keywords

Adult, Male, Regional Blood Flow, Papaverine, Humans, Middle Aged, Priapism, Phentolamine

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!