Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

The valvo-pump. An axial, nonpulsatile blood pump.

Authors: Y, Mitamura; R, Yozu; T, Tanaka; K, Yamazaki;

The valvo-pump. An axial, nonpulsatile blood pump.

Abstract

The valvo-pump, an axial, nonpulsatile blood pump implanted at the heart valve position while preserving diseased heart muscle, has several advantages over an artificial heart replacement, including 1) a good anatomic fit to the natural heart, 2) less blood contacting surface, and 3) ease of implantation. The housing for the pump is a tube, 37 mm in diameter (maximum) and 33 mm in length. Within the housing there is an impeller with either 10 vanes (33 mm in diameter) or 5 vanes (22 mm in diameter). The impeller is connected to a samarium-cobalt-rare-earth magnet direct current (DC) brushless motor measuring 23.8 mm in diameter and 30.2 mm in length. Sealing is achieved by means of a magnetic fluid seal. A guiding wheel with 4 vanes is located behind the impeller. The pump was studied on a hydraulic mock circulatory system to evaluate its performance characteristics. A pump flow of 6.9 L/min was obtained at a pump differential pressure of 48 mmHg, and flow of 3.1 L/min was obtained at 58 mmHg. The valvo-pump can be made feasible by developing a small, high-output, power motor and an endurable seal, as well as by optimizing the impeller design.

Related Organizations
Keywords

Electric Power Supplies, Heart Valve Prosthesis, Hemodynamics, Models, Cardiovascular, Humans, Equipment Design, Heart-Assist Devices

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    12
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
12
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!