Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Capillary blood viscosity in microcirculation.

Authors: CORTINOVIS, ALVISE; CAVALLI, ROSSELLA; CORTI, MAURIZIO ENRICO; CATTANEO, LUIGI; CRIPPA A.;

Capillary blood viscosity in microcirculation.

Abstract

As known, at the arteriolar level there is the highest resistance to the flow due to the section and to the velocity with an average pressure fall of 50 mmHg (from 85 to 35 mmHg). This resistance is expressed in sec(-1) by the ratio W/2r. This ratio is very high with an average value of 332 sec(-1) and viscosity at this high shear-rate is negligible. At the capillary level the pressure fall is 11.5 mmHg but the vascular resistance W/2r is much lower, on average 32 sec(-1). We can say that if a resistance of 333 sec(-1) corresponds with a pressure fall of 50 mmHg, then a resistance of 32 sec(-1) should correspond with a pressure fall of 4.8 mmHg. The highest pressure fall is due to another kind of resistance which we can define as "Capillary Blood Viscosity" because it depends on the rheological and structural characteristics of the blood. Our instrument reproduces the structure of the capillary district in an experimental model and measures the General Blood Viscosity (GBV) and the Capillary Blood Viscosity (CBV) at the same shear-rate and in particular at the low shear-rate when in non-Newtonian fluids the highest increase in viscosity appears. Consequently, at the capillary, viscosity is dominant with respect to the other geometric and physical resistances. Moreover, the percentage ratio between the GBV and the CBV gives a physical measure of erythrocyte deformability. Knowing viscosity at shear-rate present in the circulatory system, we can obtain the size of RBCs aggregates in the different circulatory districts and their characteristics expressed like "aggregation bond". Changes in CBV are the only possibility in clinical practice to improve the circulatory flow in the capillary district because it is not sure that changes in the arteriolar section can improve the capillary flow or rather open arterio-venous anastomosis. Moreover, in the systemic circulation the aggregate size allows us to point out the phenomenon of cell adhesion because the presence of several receptors involves also the other blood cells. Finally the size and the stability of the RBCs aggregates can modify the endothelial thrombo-resistance.

Country
Italy
Keywords

Erythrocyte Aggregation, Microcirculation, CAPILLARY BLOOD VISCOSITY, 610, Polycythemia, MICROCIRCULATION, Blood Viscosity, Capillaries, Arthritis, Rheumatoid, 615, Erythrocyte Deformability, Hemorheology, Intestinal Neoplasms, Diabetes Mellitus, Humans, ERYTROCYTE DEFORMABILITY

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    16
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
16
Average
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!