Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Bladder temperature versus tympanic membrane and forehead skin temperature].

Authors: Mette, Joost; Henrik, Guldager;

[Bladder temperature versus tympanic membrane and forehead skin temperature].

Abstract

The purpose of the study was to compare three different methods of assessing the core temperature: by measuring the bladder temperature, the tympanic temperature, (Braun Thermoscan 3000) and the forehead skin temperature (Philips SensorTouch). Measuring of the bladder temperature and the tympanic temperature are wellknown methods whereas measuring of the forehead skin temperature by the use of Sensor Touch is a fairly new method by which the temperature at the warmest area of the forehead is measured.Forty-two randomly chosen adult patients who all had a bladder catheter with a thermometer and a normal urine output. The patients were admitted to an intensive care unit and none were intubated nasally. Otoscopy was performed prior to temperature measurement. The temperatures were measured almost simultaneously. At the same time a white blood cell count and the C-reactive-protein value was recorded.There was a good linear coherence between the bladder temperature and the tympanic temperature (r = 0.97). The linear coherence between the bladder temperature and the forehead skin temperature was poor (r = 0.59). We found a mean deviation of 0.07 degree C and a standard deviation of 0.3 degree C of the difference between the bladder temperature and the tympanic temperature (p = 0.19). The mean of the difference between the bladder temperature and the forehead skin temperature was 0.5 degree C and a standard deviation of 0.8 degree C (p = 0.0003). Furthermore the forehead skin thermometer was not able to measure temperatures < 35.0 degrees C. We found no statistically significant coherence between the core temperature and the white blood cell count or C-reactive-protein.Tympanic temperature was well coherent with bladder temperature--forehead skin temperature was poorly coherent with bladder temperature. By evaluating the core temperature in intensive care patients the tympanic temperature is a reliable alternative to the bladder temperature.

Keywords

Adult, Male, Tympanic Membrane, Thermometers, Urinary Bladder, Body Temperature, Thermography, Humans, Female, Forehead, Skin Temperature

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!