Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Toric phakic intraocular lens: European multicenter study.

Authors: H Burkhard, Dick; Jorge, Alió; Marco, Bianchetti; Camille, Budo; Bern Jurriën, Christiaans; M Alaa, El-Danasoury; José L, Güell; +10 Authors

Toric phakic intraocular lens: European multicenter study.

Abstract

To evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after implantation of Artisan toric phakic intraocular lenses (TPIOLs) for the correction of myopia or hyperopia with astigmatism.Prospective, nonrandomized, comparative (self-controlled) multicenter trial.Seventy eyes of 53 patients (mean, 35 years; range, 22-59 years) with preoperative spherical equivalent between +6.50 and -21.25 diopters (D) and cylinder between 1.50 and 7.25 D.Seventy eyes underwent implantation of a TPIOL with an optical zone of 5.0 mm (Artisan, Ophtec, Groningen, The Netherlands). The dioptric power of the intraocular lens was calculated by considering refraction, keratometry, and anterior chamber depth. The follow-up was 6 months in all cases. Lenses were available in powers ranging from +12.0 D to -23.5 D (spherical equivalent) in 0.5-D increments, with additional cylinder from 1.0 D to 7.0 D, also in 0.5-D increments.The main parameters assessed were best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), refraction, endothelial cell count (ECC), intraocular pressure, slit-lamp biomicroscopy, indirect ophthalmoscopy, subjective complaints, and patient satisfaction.Eyes were divided into group A, myopia (n = 48), with an average preoperative spherical equivalent of -8.90 +/- 4.52 D, and group B, hyperopia (n = 22), with an average preoperative spherical equivalent of +3.25 +/- 1.98 D. No eyes in either group experienced a loss in BSCVA, and 46 eyes gained 1 or more lines of their preoperative BSCVA. In 62 eyes (88.6%), UCVA was 20/40 or better. There was a significant reduction in spherical errors and astigmatism in all cases after surgery. All eyes of both groups were within +/-1.00 D of target refraction, and 51 eyes (72.9%) were within +/-0.50 D of target refraction. There was a 4.5% mean total loss of ECC during the first 6 months. No serious complications were observed. Overall patient satisfaction was very high.Six-month clinical trial results demonstrate that implantation of the Artisan TPIOL safely, predictably, and effectively reduced or eliminated high ametropia and astigmatism with one procedure. The refractive effect was stable at 6 months after surgery.

Keywords

Adult, Lenses, Intraocular, Male, Endothelium, Corneal, Visual Acuity, Astigmatism, Cell Count, Middle Aged, Refraction, Ocular, Hyperopia, Postoperative Complications, Lens Implantation, Intraocular, Lens, Crystalline, Myopia, Humans, Female, Prospective Studies, Safety, Intraocular Pressure

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    131
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 1%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 1%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
131
Top 10%
Top 1%
Top 1%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!